Functional description, 1 base unit, Chapter 2 functional description – CANOGA PERKINS 9145E Network Interface Device User Manual

Page 17

Advertising
background image

Functional Description

9145E Ethernet Network Interface Device User’s Manual

Base Unit

5

2.1 Base Unit

The 9145E is designed with front-panel data and management ports and rear-panel power and

ground connectors. This design allows for a multitude of power and port options. The 9145E is

available as a normal (see Table 2-1) or hardened (see Table 2-2) unit. In addition, both 9145Es

come as Standard NID (V2 engine), or as an Enhanced NID (V1 engine) units. Both types of

9145E are able to accommodate feature enhancements through firmware upgrades.

Table 2-1. 9145E Model Numbers and Configuration

MODEL

NUMBER

EXTENDED DESCRIPTION

9145E-101-0-0

V1 Engine, UTP/SFP User Port, UTP/SFP Network Port, UTP/SFP Multipurpose Port, Local

Ethernet UTP Management Port, Single AC Power Supply, Integral Fans

9145E-101-1-0

V1 Engine, UTP/SFP User Port, UTP/SFP Network Port, UTP/SFP Multipurpose Port, Local

Ethernet UTP Management Port, Single 48VDC Power Supply, Integral Fans

9145E-101-2-0

V1 Engine, UTP/SFP User Port, UTP/SFP Network Port, UTP/SFP Multipurpose Port, Local

Ethernet UTP Management Port, Redundant AC Power Supply, Integral Fans

9145E-101-3-0

V1 Engine, UTP/SFP User Port, UTP/SFP Network Port, UTP/SFP Multipurpose Port, Local

Ethernet UTP Management Port, Redundant 48VDC Power Supply, Integral Fans

9145E-101-4-0

V1 Engine, UTP/SFP User Port, UTP/SFP Network Port, UTP/SFP Multipurpose Port, Local

Ethernet UTP Management Port, Redundant AC/48VDC Power Supply, Integral Fans

9145E-104-0-0

V1 Engine, UTP/SFP User Port, UTP/SFP Network Port, Single AC Power Supply, Integral Fans

9145E-104-1-0

V1 Engine, UTP/SFP User Port, UTP/SFP Network Port, Single 48VDC Power Supply, Integral

Fans

9145E-104-2-0

V1 Engine, UTP/SFP User Port, UTP/SFP Network Port, Redundant AC Power Supply, Integral

Fans

9145E-104-3-0

V1 Engine, UTP/SFP User Port, UTP/SFP Network Port, Redundant 48VDC Power Supply, Inte-

gral Fans

9145E-104-4-0

V1 Engine, UTP/SFP User Port, UTP/SFP Network Port, Redundant AC/48VDC Power Supply,

Integral Fans

9145E-203-5-0

V2 Engine, UTP/SFP User Port, UTP/SFP Network Port, Single AC Power Supply

9145E-203-6-0

V2 Engine, UTP/SFP User Port, UTP/SFP Network Port, Single 48VDC Power Supply

9145E-203-7-0

V2 Engine, UTP/SFP User Port, UTP/SFP Network Port, Redundant AC Power Supply

9145E-203-8-0

V2 Engine, UTP/SFP User Port, UTP/SFP Network Port, Redundant 48VDC Power Supply

9145E-203-9-0

V2 Engine, UTP/SFP User Port, UTP/SFP Network Port, Redundant AC/48VDC Power Supply

Chapter 2

Functional Description

Advertising