9145E Ethernet Network Interface Device User’s Manual

Functional Description

Service Data Ports

8

2.2.2 Rear Panel

Customers will also have a selection of power options to choose from (see Figure 2-2). Five

options are offered:

1. Single AC Power
2. Redundant AC Power
3. Single DC Power
4. Redundant DC Power
5. Redundant AC and DC mix

Figure 2-2. 9145E Rear Panel

The Standard and Enhanced versions of the normal 9145E accommodate all five power options.

Both the Standard and Enhanced versions of the hardened 9145E are limited to 24 VDC or

48VDC power options.

2.3 Service Data Ports

The Service Data Ports (see Figure 2-1) provide both fixed UTP and SFP connectors. The user

can configure the 9145E through software to allow for either the UTP or SFP connector within

each port to be active. Both connectors can not be active simultaneously.

UTP connectors are IEEE802.3 compliant for 10/100/1000BASE-T.

UTP connectors support MDI and MDIX connections.

UTP connectors support both full-duplex and half-duplex operation in 10/100/1000 Mbps

mode.

SFP connectors support full-duplex operation in 10/1000 Mbps mode.