Troubleshooting, 1 optical power loss, 2 fault conditions – CANOGA PERKINS 9145E Network Interface Device User Manual

Page 43: 1 remote fault (rmtf), Chapter 5 troubleshooting

Advertising
background image

Troubleshooting

9145E Ethernet Network Interface Device User’s Manual

Optical Power Loss

31

This chapter covers identifying fault conditions and determining corrective action. The front panel

LEDs provide both normal and fault information. To aid troubleshooting, Tables 5-1and 5-2 list all

LED functions and indications.

5.1 Optical Power Loss

Whenever there is a significant signal loss, the Rx indictor turns off. Check cable integrity, and

remove and inspect the cable connectors, being careful not to damage the fiber end-face surface

or the connector housing. Clean all optical connectors before reinstalling them.

5.2 Fault Conditions

The 9145E front panel and interface module LEDs show fault conditions. Additional information

about fault conditions appears on the System Alarms Log. Use the System Alarms Screen to

view alarms and faults on the 9145E (reference 6913303, 9145E NID Software Version 1.0 Users

Manual).

5.2.1 Remote Fault (RMTF)

If an optical port loses the RX optical signal, it sends a Remote Fault (RMTF) signal on its Trans-

mit to the distant end on the optical link. The SPD LED is off, and an alarm flags the link loss on

the optical port. When an optical port receives a Remote Fault signal, the ACT/LNK LED lights

red and an alarm flags the remote side optical link failure. Both local and remote link partners

must be configured to the same RMTF enable/disable setting (See Figure 5-1).

Figure 5-1. Remote Fault Signal

Tx

Rx

Rx

Tx

x

RMTF

USER
PORT

NETWORK

PORT

LOCAL DEVICE

Tx

Rx

Rx

Tx

USER
PORT

NETWORK

PORT

REMOTE DEVICE

Local device ACT/LNK detects link loss

Tx transmits RMTF to remote device

Local device ACT/LNK turns OFF

Remote device ACT/LNK turns red

Chapter 5

Troubleshooting