3 calculating fiber link attenuation, Calculating fiber link attenuation – CANOGA PERKINS 9145E Network Interface Device User Manual

Page 51

Advertising
background image

Maintenance

9145E Ethernet Network Interface Device User’s Manual

Check Optical Power Levels

39/(40 Blank)

Figure 6-2. Measuring Receiver Input Power

6.2.3 Calculating Fiber Link Attenuation

Link attenuation measurement identifies potential problems with links that are on the threshold of

receiver sensitivity. Measure optical fiber links at the shortest wavelength of operation, as it is the

limiting factor in the loss budget. Use a power meter calibrated for the laser source, then factor in

approximately 1 dB for the connector loss from the patch cables between the 9145E and the

local device. (Each fiber connection can generate 0.5 dB of additional loss.)

NOTE: If you cannot determine the Rx sensitivity, contact Canoga Perkins

Technical Support for assistance.

Follow these steps to calculate fiber link attenuation:

1. Determine transmitter output power as described in paragraph 6.2.1 above.

2. Determine receiver input power as described in paragraph 6.2.2 above.
3. Subtract receiver input power from transmitter output power. The result is the fiber link

attenuation.

Transmit Output Power -7.0 dBm

Receiver Input Power -28.2 dBm

Fiber Link Attenuation 21.2 dB

FIBER OPTIC
TRANSMITTER

FIBER OPTIC
RECEIVER

OPTICAL

POWER

METER

-24dBm

λ

= 1300 nm

FIBER OPTIC
TRANSMITTER

FIBER OPTIC
RECEIVER

OPTICAL

POWER

METER

-24dBm

λ

= 1300 nm

LOCAL SITE

REMOTE SITE

Advertising