Fuel computer, Fuel computer -2 – Dynon Avionics EMS-D120 Pilots Users Guide User Manual

Page 34

Advertising
background image

EMS Operation

7-2

EMS-D120 Pilot’s User Guide

the system, you must press BRITR on any bright screen unit to get the bright screen units to their final step of
brightness.

The HS34 and AP74 have a built-in light sensor which can be used to automatically dim all of the screens
connected to a DSAB network. To turn this function on, press AUTODIM. When you enable auto-dim, the
screen does not immediately change brightness. Instead, the system records the unit’s current brightness level as
the desired brightness. From that point on, all networked units react to changes in light intensity and maintain
perceived brightness at the desired level. If auto-dim is enabled and the screen is too bright or dark, continue to
use the BRITR or DARKR buttons as you would without auto-dim. The system records the new set level as the
desired brightness, and auto-adjusts around the new set point.

Fuel Computer

The fuel computer can be programmed in EMS > SETUP > FUEL > ADD THRESHOLD to automatically detect the
addition of fuel while the unit is turned off. When this is configured, the next time you turn the FlightDEK-D180 on, it
asks you if you added fuel and gives you a shortcut to the add fuel menu. See the EMS-D120 Installation Guide for more

on configuring the fuel sensors and fuel computer.

information

Add Fuel: EMS > FUEL > ADD > INC+/DEC- > SEL► > ACCEPT/CANCEL

Use this to add to or subtract fuel from the EMS Fuel Computer. Press INC+ to add fuel. Press DEC- to subtract fuel.
Press SEL► to enter the value into the computer. Press ACCEPT to confirm the value. Press CANCEL if the value is
not correct. Note that you can also access the FUEL menu from the Auxiliary page, if you have the fuel computer info
item displayed on it.

Reset fuel level to pre-configured value: EMS > FUEL > PRESET

Advertising