Engine leaning, Clock setup, Engine leaning -3 – Dynon Avionics EMS-D120 Pilots Users Guide User Manual

Page 35: Clock setup -3

Advertising
background image

EMS Operation

EMS-D120 Pilot’s User Guide

7-3

You may configure the PRESET value using the following path: EMS > SETUP > FUEL > PRESET VALUE >
INC+/DEC- > BACK.

Reset fuel level to full: EMS > SETUP > FUEL > FULL

You may configure the FULL value using the following path: EMS > SETUP > FUEL > FULL VALUE > SEL► >
INC+/DEC- > BACK.

Note: It is necessary to calibrate the EMS Fuel Computer with the sensors for fuel level to work correctly. See the EMS-
D120 Installation Guide for more details.

Engine Leaning

Enter Lean Mode: EMS > LEAN

This puts the EGT display into lean mode, changing the numerical values for each cylinder to the format “order peaked-
temperature below peak.”

Exit Lean Mode: EMS > LEAN

This returns the EGT display to normal.

Clock Setup

Set Time: EMS > TIMES > CLOCK > SEL► > INC+/DEC- > BACK

This menu, and corresponding dialog box, allows you to set both your local time and Zulu time in 24-hour format. You
may display times in either 12-hour or 24-hour format as described in the next section. Set the local and Zulu times
independently. Highlight values using SEL►. Adjust highlighted values with INC+/DEC-. Each time a button is
pressed, the value changes by one. Hold down INC+ or DEC- to adjust values rapidly. Seconds are reset to zero when