EMS Operation

Change power on alarms status: EMS > SETUP > GLOBAL > ALARM CONFIG > PWR ON ALARMS

Set this parameter to “ON” to enable alarms before engine startup. When set to “OFF”, all alarms are suppressed
whenever ALL of the following conditions exist:

 RPM less than 400
 Oil pressure less than 20 PSI
 First five minutes after master instrument power applied

All alarms are enabled when any of the above conditions are exceeded.

Note: The alarm light (if installed and configured) will flash whenever an alarm condition exists; it is not inhibited by
setting PWR ON ALARMS to OFF.

Test light/audio alarm(s): EMS > SETUP > GLOBAL > ALARM CONFIG > TEST ALARM LIGHT/AUDIO

Note: You must select an alarm to test using the UP▲/ DOWN▼ buttons. Hold SEL► to test the selected alarm.

Info Item Configuration: EMS > SETUP > GLOBAL > INFO
ITEM CONFIG►

The INFO ITEM CONFIG submenu allows you to configure a
variety of different sensors as simple analog bars, on/off
contacts, or text items.

The first two info items are displayed on the EMS Main Page.
Info item 1 is at the top right of the page, and info item 2 is at
the lower right of the page. The other six info items are located
on the Aux Page and are numbered 3 through 5 on the top row

7-6