Gp output table – Dynon Avionics EMS-D120 Pilots Users Guide User Manual

Page 43

Advertising
background image

Appendix

8-4

EMS-D120 Pilot’s User Guide

GP output table

General purpose inputs have a unique format in the data output stream. As shown in the table above, they each have 8
characters. 3 are used as a label for the function; 5 are used for the data. As noted above, general purpose inputs sourced
from the HS34 are not included in this table.

Description

Units

Label (3-Bytes)

Example (5-Bytes)

Unused

N/A

XXXXX (‘X’s are output as place holders)

OAT

ºF

OAT

00123 (123 ºF) or –0123 (-123 ºF)

Carb Temp

ºF

CRB

00123 (123 ºF) or –0123 (-123 ºF)

Coolant Temp

ºF

CLT

00123 (123 ºF) or –0123 (-123 ºF)

Coolant Pressure

PSI

CLP

00123 (12.3 PSI)

Fuel Level 3

Gallons x 10

FL3

00123 (12.3 gal)

Fuel Level 4

Gallons x 10

FL4

00123 (12.3 gal)

CHT CHT

Aileron Trim

% of full

deflection

TRA

0061 (61%)

Elevator Trim

% of full

deflection

TRE

0061 (61%)

Rudder Trim

% of full

deflection

TRR

0061 (61%)

Flap Position

º

FLP

00010 (10º)

As an example, the following is one line of EMS data:

0012224826351340262441240122631320562191191OAT00090TRE-0061FLP0001020481378139214
061421143514503583533633743843951103D2