Appendix

9-2

FlightDEK-D180 Installation Guide

in the menu system. The battery may charge to as high as 16.8 volts, but it is only
necessary to charge it to 16.0 volts for this test.

2. Remove all sources of external power from the FlightDEK-D180, ensuring that it is

operating off its internal battery.

3. Ensure that the screen is at its full brightness level. To do this, enter the menu system by

pressing any button beneath an EFIS page (except the far left or far right hotkeys) and
press MORE > DIM and increase the brightness until it will not increase anymore.

4. Let the unit remain on for 1.5 hours.
5. If, after these 1.5 hours, your FlightDEK-D180 has not turned off and does not display

the INTERNAL BATTERY LOW warning, your battery passes the capacity test.

6. Make sure you recharge your battery; a full charge is reached when the voltmeter shows

at least 16.0 volts on the internal battery.

If your battery does not pass the above test, please contact Dynon Avionics and refer to
Appendix G for battery replacement instructions.

Please dispose of non-functional backup batteries in a responsible manner. Backup
batteries are lithium-ion and similar in construction to cordless tool batteries. They can
likely be recycled wherever cordless tool battery recycling is available. For a list of
recycling locations in your area (USA only), call 1-800-8-BATTERY or see the Call 2
Recycle website at www.rbrc.org.

FIRMWARE UPGRADE

Dynon Avionics provides free firmware updates for all its products, and continues to add new
features periodically. We suggest that you regularly ensure that your FlightDEK-D180 has the
latest firmware by visiting our website at

downloads.dynonavionics.com

and downloading the

latest Dynon Product Support Program. This software contains the latest firmware updates for all
our products.

Each Dynon EMS or EFIS must be individually upgraded by connecting a PC to that
instrument’s serial port. The HS34 also must be individually upgraded via its Serial 1 port.
Firmware upgrades to EDC-D10A, AP74, and SV32/42/52 are performed automatically during
firmware upgrades of the attached EFIS product. (Upgrading a non-DSAB-bus-master EFIS will
not update attached autopilot devices).