Global parameters setup, Global parameters setup -3 – Dynon Avionics FlightDEK-D180 Installation Guide User Manual

Page 61

Advertising
background image

EMS

Configuration

When you modify one value, it will not “push” another value up or down. So, in the example
above, you would not be able to increment the HI YEL/GRN parameter beyond 95 until you
increased the HI RED/YEL parameter. Likewise, you would not be able decrement the HI
RED/YEL value below 90 until you decrease the HI YEL/GRN parameter.
To disable alarms before engine start, enter the EMS > SETUP > GLOBAL > ALARM CONFIG
menu. Set PWR ON ALARMS to OFF. With this parameter set to “OFF”, all alarms are
suppressed whenever ALL of the following conditions exist:

 RPM less than 400
 Oil pressure less than 20 PSI
 First five minutes after master instrument power applied

All alarms are initialized when any of the above conditions are exceeded.

Global Parameters Setup

When in the SETUP menu, press GLOBAL to
bring up the full-screen menu seen at right. D
installation, you only need to deal with the items
under the INSTALL SETUP section. During
install, you may want to change the units to the
setting that is convenient for you. If you are not
the intended pilot using the instrument, he or she
may easily change units to whatever they desir
without affecting calibration or configu
Refer to the FlightDEK-D180 Pilot’s User Gu
for more detailed information about the PILOT SETUP and SCREEN SETUP sections of the
GLOBAL menu.

uring

e

ration.

ide

nd

s in

Press DOWN▼ until you have selected the item, # OF CHT. Press SEL► until the number
shown reflects the number of cylinder head temperature sensors installed on the engine. For
Rotax 9-series engines, select 2 to indicate the fact that the EMS will
be monitoring the left and right pairs of cylinders.

Split display

Combined display

Press DOWN▼ to select the item, # OF EGT. Press SEL► until the
number shown reflects the number of exhaust gas temperature sensors
installed on the engine.
Press DOWN▼ to select the item, CYL DISP. Press SEL► to toggle
between SPLIT and COMBD. The split display presents CHTs and
EGTs in separate locations as horizontal bars, and is available for 2 a
4 cylinder displays. The combined display presents CHTs and EGT
the same location with EGTs as horizontal bars, and CHTs as tics on
the bars.
Press DOWN▼ to select the item, # OF FUEL TANKS. Press SEL►
until the number shown reflects the number of fuel tanks included on
the aircraft.

FlightDEK-D180 Installation Guide

6-3