Configuration

COOLANT TEMPERATURE

Sensor

Type

Coolant Temp

Sensor

1 Dynon

P/N

100409-001

2

Chevrolet LS7 pre-

installed

3 Dynon

P/N

100409-000

4 Rotax

801-10-1

Sensor

Type

Coolant Pressure

Sensor

1 Dynon

P/N

100411-000

Sensor

Type

OAT Sensor

1

Dynon P/N 100433-000

(2-wire)

Dynon P/N 100433-001

(3-wire, when installed

as described on page 3-

13)

2 GRT

OAT-01

Under the desired GP input number, set FUNCT to
COOL TEMP. Select the analog bar thresholds as
described in the Alarm and Color Threshold
Configuration
section on page 6-2. Set the SENSOR
TYPE to the correct number using the sensor type table.

COOLANT PRESSURE

Under the desired GP input number, set FUNCT to
COOL TEMP. Select the analog bar thresholds as
described in the Alarm and Color Threshold
Configuration
section on page 6-2. Set the SENSOR
TYPE to the correct number using the sensor type table.

OUTSIDE AIR TEMPERATURE SENSOR

Under the desired GP input number, set FUNCT to
OAT. Select the analog bar thresholds as described in
the Alarm and Color Threshold Configuration section on
page 6-2
. Set the SENSOR TYPE to the correct number
using the sensor type table.
If you have installed a Dynon Avionics OAT to a
General Purpose Input enter the EMS setup menu by
pressing SETUP > SENSOR > EMS GP INPUT. Set the
desired GP Input to OAT and select sensor type 1.

If the OAT is connected to the EMS D37
connector, do not set the sensor type in the EFIS > SETUP > OAT menu. Ensure that the
INSTALLED value in the EFIS OAT menu is set to N.

AILERON TRIM

Under the desired GP input number, set FUNCT to TRIM AILRN. There are no alarm thresholds
or any other setting required for aileron trim.

ELEVATOR TRIM

Under the desired GP input number, set FUNCT to TRIM ELEV. There are no alarm thresholds
or any other setting required for elevator trim.

RUDDER TRIM

Under the desired GP input number, set FUNCT to TRIM RUDR. There are no alarm thresholds
or any other setting required for rudder trim.

FLAP POSITION

Under the desired GP input number, set FUNCT to FLAP POS. There are no alarm thresholds or
any other setting required for flap position.