External ems warning light, Audio alert outputs, External ems warning light -10 – Dynon Avionics FlightDEK-D180 Installation Guide User Manual

Page 48: Audio alert outputs -10

Advertising
background image

Instrument Installation

External EMS Warning Light

EMS DB37 Pin 29 can be wired and configured
as an external warning light, or alternatively, to
automatically control cabin light levels in sync
with the screen brightness of the Dynon
instruments.
To wire EMS DB37 Pin 29 as an external
warning light, you may connect any standard
LED or incandescent lamp (1.5 watts maximum),
used during EMS-related alarm conditions.
Ensure that the LED or lamp is designed for the voltage of your system. Mount it to your panel
according to its recommendations. Connect one of the lamp’s leads to your plane’s power.
Connect the other lead to pin 29 on the FlightDEK-D180 37-pin wiring harness. During an alarm
condition, this pin is connected to ground, causing current to flow through the lamp.
To configure EMS DB37 Pin 29 as an external warning light, enter the EMS menu by pressing
any button beneath an EMS main page. Press MORE > SETUP > GLOBAL. Press DOWN▼ to
select ALARM CONFIG and press SEL. LGT BHVR: ACK SOLID configures the external
alarm light to remain on (solid) when the alarm condition is acknowledged. LGT BHVR: ACK
CLEAR configures the external alarm light to go off when the alarm condition is acknowledged.
Verify correct operation of the external EMS warning by using the test function in the GLOBAL
menu. Enter the EMS menu by pressing any button beneath an EMS main page. Press MORE >
SETUP > GLOBAL. Press DOWN▼ to select ALARM CONFIG and press SEL. Select TEST
ALARM LIGHT and follow the instructions to test external light functionality.
Dimmer mode function is generally used only by Original Equipment Manufacturers (OEMs). In
dimmer mode, the output of EMS DB37 Pin 29 is a Pulse Width Modulation (PWM) signal
proportional to the screen brightness setting of the Dynon instruments. To configure EMS DB37
Pin 29 for dimmer mode, enter the EMS menu by pressing any button beneath an EMS main
page. Press MORE > SETUP > GLOBAL. Press DOWN▼ to select ALARM CONFIG and
select LGT BHVR: DIM OUTPT.

EMS

DB37

Pin

Color

Function

29 Yellow/Green

External

warning light

/ Dimmer

control

DB25

Pin

Color

Function

18

Green

EFIS Audio Alert Output

DB37

Pin

Color

Function

31 White/Orange

EMS Audio Alert

Output

Audio Alert Outputs

The FlightDEK-D180 has two audio
alarm outputs: one for sounding EMS-
related alarms, and one for sounding
AOA and altitude alarms sourced from
the EFIS. If you plan to use both alarm
outputs, connect these outputs (whose
pin numbers are shown in the tables at
right) together and then to the outside
terminal of a 10 kΩ variable resistor (not
included) as shown below. If you only
plan to use one of the audio alarm

4-10

FlightDEK-D180 Installation Guide

Advertising