Adapter end cover (2.2), 000m, End covers, contd – Leica Geosystems Leica DISTO Pro User Manual

Page 23

Advertising
background image

25

DISTO™ pro

4

/ pro

4

a-1.0.0en

English

en

End covers, contd.

DISTO changes to Normal

mode and displays basic

settings. The symbol for the

instrument without end cover

appears.

Avoid using DISTO without

end cover as the battery

cover is then exposed and may be

damaged.

Adapter end cover (2.2)

The settings for how the adapter end

cover will be used are made here.

These settings determine the rear

reference of the DISTO.

Default setting: none, meaning that

after a reset all settings remain.

Without add-on (2.2.1)

Select this menu function when the

adapter end cover is used without

any further add-ons.

After pressing the Enter key a short

confirmation appears and the menu

function is terminated.

DISTO changes to Normal

mode and displays the

symbol of the adapter end

cover in the basic settings.

Accessory 723775 (2.2.2)

This menu function sets rear

reference to the adapter end cover

with the optional short bracket (read

User Information, Accessories).

After pressing the Enter key a short

confirmation appears and the menu

function is terminated.

DISTO changes to Normal

mode and displays the basic

settings. The symbol of a

special adapter appears.

Accessory 723776 (2.2.3)

This menu function sets rear

reference to the adapter end cover

with the optional long bracket (read

User Information, Accessories).

After pressing the Enter key, a short

confirmation appears and the menu

function is terminated.

DISTO changes to Normal

mode and displays basic

settings. The symbol of a

special adapter appears.

Set pivot gap (2.2.4)

Set pivot gap in this menu function

when a stand is used with the

adapter end cover.

To adjust rear reference, the distance

from the rear side of the adapter end

cover to the rotation axis of the stand

has to be entered.

For stand SLIK U9000,

recommended for use with

DISTO, this distance is0.054 m.

The last saved entry for the pivot gap

between adapter end cover and the

rotation axis of the stand is

displayed.

Enter new pivot gap with keypad,

recall value from keypad memory or

from the stack.

Brief press confirms entry.

Renewed press quits menu.

A short confirmation is displayed and

the DISTO changes to Normal mode.

adapter end cover

2.2

1 without add-on

2 accessory 723775

3 accessory 723776

4 pivot gap

5 individual extension

0.000m

pivot gap

2.2.4

After calling up the menu function,

the following is displayed:

Advertising