5.1 Quit online-mode (STD or B)
Function:
Switches DISTO
TM
pro
4
/ DISTO
TM
pro
4
a to offline mode
Input:
STD<cr>
or B<cr>
Output:
?<cr><lf>
or @Exxx<cr><lf>
5.2 Distance measurement (G)
Function:
Trigger single measurement with short output, like „g“
Input:
G<cr>
Output:
WI31<cr><lf>
or @Exxx<cr><lf>
5.3 Tracking (H)
Function:
Triggers continuous distance measurement with short edition. Measurement
is continued until next command or until an error occurs., like „h“.
Input:
H<cr>
Output:
WI31<cr><lf>
or @Exxx<cr><lf>
Remarks:
Interface must be set to 9600 baud or higher to fully exploit the measuring
rate.
5.4 Set baud rate (N70N)
Function:
Set baud rate with fixed parity (None Parity) and fixed databits (8 databits).
Input:
N70N%1N<cr>
%1. Parameter:
Baud rate:
1
600 baud
2
1200 baud
3
2400 baud
4
4800 baud
5
9600 baud
6
19200 baud
Output:
?<cr><lf>
(with old baud rate) or @Exxx<cr><lf>
Remarks:
Settings are immediately stored in the EEPROM!
5.5 Back light on/off (LIGHT)
Function:
Switches LED on /off.
Input:
LIGHT %1<cr>
%1. parameter
0
Back light off
1
Back light on
Output:
?<cr><lf>
or @Exxx<cr><lf>
5.6 Delete display (CDISP)
Function:
Deletes display contents
Input:
CDISP<cr>
Output:
?<cr><lf>
or @Exxx<cr><lf>