Leica Geosystems Leica DISTO pro /pro4a - interface manual User Manual

Page 13

Advertising
background image

3350-RUEA

Error! Style not defined.

I:\DIST\Marketing\0Temp\Doc\interfaceManual111_en.docSeite 13 von 18

Erstelldatum: 17.06.03

Displaced

6

Writes „Online Disto“

Output:

?<cr><lf>

or @Exxx<cr><lf>

5.11 Read keypad (KEY)
Function:

Enables keypad to be read.

Input:

KEY %1<cr>

%1. Parameter

x coordinate

<=0

Waits on key

>0
(max.
30000)

Timeout [ms] to read key

Output:

WI5000<cr><lf>

or @Exxx<cr><lf>

5.12 End cover output (ENDCOVER)
Function:

Outputs end cover code

Input:

ENDCOVER<cr><lf>

Output:

WI202<cr><lf>

or @Exxx<cr><lf>

Remarks:

3 = no magnet, 2 = one magnet at the left (swivel foot),1 = one magnet at the
right (alignment aid), 0 = two magnets

5.13 Output beep sound (BEEP)
Function:

Emits beep sound.

Input

BEEP %1<cr>

%: Beep length 0..5000 [ms]

Output:

?<cr><lf>

or @Exxx<cr><lf>

5.14 Delete all data (DELALLDATA)
Function:

Deletes all data sets!

Input:

DELALLDATA<cr>

Output:

?<cr><lf>

or @Exxx<cr><lf>

5.15 Read memory (GETDATA)
Function:

Reads data memory.

Input:

GETDATA %1 %2<cr>

%1. Parameter

n

Starting range (n larger than, equal to 1)

%2. Parameter

n

End range (n smaller than equal to 800)


Output:

WI11 WI31 or WI22 or WI314 or WI315 WI71 WI72 WI73<cr><lf>

?<cr><lf>

or @Exxx<cr><lf>

Remarks :

Every data set ends with a terminator.

From 1 to 800 data set can be transmitted.

After the last data set has been transmitted, a “?“ appears as confirmation of
the end of the function.

Advertising