Appendix, Example, A1 example – Eclipse Combustion EGA4 User Manual

Page 48: Ecoline 4000, 9% co, 0% co 1

Advertising
background image



Instruction Manual MM850481 ed.01

APPENDIX

A1 Example

The following steps show how you can make a quick measurement using the EGA4 portable analyzer.

1. Switch

EGA4 on. It will begin the autozero and the autodiagnostic procedure. System error and trouble will be

displayed if encountered.

EcoLine 4000

Serial Num: 1257
Version : 1.001


! Don t insert !
! probe in chimney !

Op.: Antonio
Bat: 5.2V (23.5°C)
Autozero: 180 sec

MENU

MEASURE


2. Select the combustible used by burner. It is possible choosing between 4 preset and other 6 customizable types.

! Now insert !
! probe in chimney !

--- FUEL --

Natural Gas

TAG SELECTION

ANALYS.


3. Connect the sampling probe electrical and pneumatic terminals to the EGA4.

4. Insert the sampling probe in chimney. Be sure for mechanical positioning and flue gas intercepting.

5. Press

ANALYSIS] (F1) key to start the measurements. Select the desired data page using [▲] and [▼] keys. Zoom

in or out to enlarge or reduce the visualized characters using the [X] and [W] keys.

O

2

20.9%

CO

2

0.0%

CO 1

ppm

Ref O2

O2 20.9%

:

CO 2000p

Ta 20.2C

:

Eff 0.99

Tf 400.3C

:

NO2 100p

η 95.7%

:

CO2 10.2p

:

NOx 500p

:

Ref O2


6. Finishing

measurement procedure, press the [PRINT] key to print one or more reports.

PRINT

MEASURE HOLD

PRESS [PRINT]

NO. COPY 1

MODEL Standard

ESCAPE

FEED


7. Dismount the system and switch it off. All system can be put back in a rugged and practical case.

48