m

-

control

Supported Remote Control Features

When using Pro64’s m‑control feature, note that only parameters available natively on the Yamaha control surface

itself and supported by the Yamaha interface can be controlled on Pro64 mic preamps remotely. These include

channel preamp gain, low cut filter (referred to as a high pass filter in the Yamaha interface), and +48V phantom

power on the 6416m and AllFrame. The 6416m has a fixed 85Hz low cut filter, while Yamaha consoles offer a

variable range High Pass Filter (abbreviated as HPF) in their user interface. When using Yamaha remote control

with Aviom preamps, you can turn this filter on and off, but the cutoff frequency remains fixed at 85Hz. Editing

the HPF filter cutoff frequency from the Yamaha user interface will have no effect at the Pro64 mic preamp; the

cutoff frequency remains fixed at 85Hz.

The Pro64 mic preamp’s pad setting is controlled indirectly through the head amp gain setting on the console.

There is no direct command for turning the Pro64 mic preamp pad on or off from the Yamaha control surface.

Physical Connections

Remote control commands between the Yamaha host console and Pro64 remote mic preamps are sent

using RS‑422 communication. Many Yamaha devices have DB9 RS‑422 jacks on their rear panel, while some

others send remote control communication directly to external devices via the console’s multipin backplane

connector where the MY format expansion cards connect to the console’s circuit board.

For Yamaha devices with a DB9 jack for remote HA control, a DB9 serial cable must be used to connect the console

to the 6416Y2 card set up for m‑control. No additional connections are required anywhere in the network, as all

remote control commands are managed by the Pro64 devices and transmitted via the network cabling.

In Pro64 systems where more than one 6416Y2 A‑Net Interface Card is installed in a Yamaha console, only one of

the 6416Y2 cards should be set to provide m‑control communication and messaging between the Yamaha host

and the Pro64 network. This one card will manage remote control communication for all 6416Y2 cards in the host

console. This card must be installed in the Yamaha device’s expansion slot #1.