Brookfield CT3 Texture Analyzer User Manual

Page 44

Advertising
background image

Brookfield Engineering Labs., Inc.

Page 44

Manual No. M08-372-C0113

ACCESSORIES FOR FIXTURE BASE TABLE

TA-BT-KIT

FIXTURE BASE TABLE

Rectangular base table with removable insert, which is used as a test surface. All
accessories listed below mount into this table when the insert is removed. Pair of
T-Bolts for securing the table are included. Four sets of extension legs (1, 1.5, 2
& 4 Inches) are supplied. Extra extension legs may be purchased separately.

TA-BT-3KY Set of four 1 inch table leg extensions

TA-BT-2KY Set of four 1.5 inch table leg extensions

TA-BT-7KY Set of four 2 inch table leg extensions

TA-BT-8KY Set of four 4 inch table leg extensions

TA-BT-6KY Set of two thumbscrews for base table insert

ALL ACCESSORY FIXTURES BELOW MOUNT ONTO FIXTURE BASE TABLE


TA-AACC21

AACC RECOMMENDED 21mm DIAMETER PROBE

Aluminum Cylinder, 21mm D and 40mm L. Requires Fixture Table Base TA-
BT-KIT.

TA-AACC36

AACC SPEC PROBE (36mm)

This probe is used for measuring bread firmness and performing texture profile
analysis (TPA). Requires Fixture Table Base TA-BT-KIT.

TA-BLS

BILAYER SHEAR TEST FIXTURE

This fixture uses a guillotine blade to separate a bilayer tablet while measuring
shear strength. Requires Fixture Base Table TA-BT-KIT.

TA-BPS

BLISTER PACK SUPPORT TEST FIXTURE

This fixture is used to measure the force required to remove the tablet from its
blister pack. Requires Fixture Base Table TA-BT-KIT.

TA-CEF

CHEESE EXTENSIBILITY FIXTURE

This fixture measures the extensibility of a smaple, such as molten cheese, to
break point.

TA-CJ

CONFECTIONERY JIG

This fixture is used for holding candies and similar products for penetration
testing. Requires Fixture Base Table TA-BT-KIT. Consists of bases and top
plates with holes 4mm, 8mm and 12mm in diameter to allow through penetration
of samples with probes slightly smaller than holes. One blank plate (no hole) is
also included to serve as a test surface when needed.

TA-CKA

CRAFT KNIFE ADAPTER

This adapter cuts cleanly into and through material with minimum deformation
of the sample. Requires Fixture Base Table TA-BT-KIT.

TA-CLT

CAPSULE LOOP TENSILE TEST FIXTURE

This fixture is used to measure the force required to split on half of a hard gel
capsule. Requires Fixture Base Table TA-BT-KIT.

TA-CSF

CIRCULAR SUPPORT FIXTURE

This fixture provides support for round samples and retains any potential fluid
expressed during the test. Requires Fixture Table Base TA-BT-KIT.

Advertising