Appendix

: Lightning Proof and Surge Signal Proof

The product adopts TVS lightning proof technology to prevent from damage by lightning

strike below 1500 W and impulse signals such as surge; but it is also necessary to abide by the

following precautions to ensure electrical safety based on practical circumstances:

l Keep the communication cables at least 50 meters away from high voltage equipment or

cables.

l Make outdoor cable laying-out under eaves as possible as you can.

l In open area shield cables in steel tube and conduct a single point ground to the tube.

Trolley wire is forbidden in such circumstances.

l In strong thunderstorm or high faradic zone (such as high voltage transformer substation),

extra strong lightning proof equipment must be installed.

l Take the building lightning proof requirements into account to design the lightning proof

and grounding of outdoor equipment and cable laying-out in accordance with the national

and industrial standards.

l The system must be grounded with equal potentials. The earth ground connection must

satisfy the anti-interference and electrical safety requirements and must not short circuited

with high voltage electricity net. When the system is grounded separately, the resistance

of down conductor should be ≤ 4Ω and the sectional area of down conductor should be

≤25mm2