2. Setup of Coding Switch of Dome Camera.

As shown in Figure 2, SW1 is used to

set address of the dome camera from 1 – 1023. The coding switches from DIP-10 to
DIP-1 are equivalent to a 10-bit binary digital. DIP-10 is MSB while DIP-1 is LSB. The
state “ON” of each bit means 1 while “OFF” means 0. Following table shows states of
coding switches of some addresses.

Dome

Address

States of Coding Switches

DIP-1

DIP-2

DIP-3

DIP-4

DIP-5

DIP-6

DIP-7

DIP-8

DIP-9

DIP-10

1

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

2

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

3

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

4

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

5

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

6

OFF

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

7

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

8

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

9

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

10

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

11

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

12

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

13

ON

OFF

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

14

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

15

ON

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

16

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

17

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

18

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

1023

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

Table 1

For Example:

3. Setup of the Protocol and the Default Baud Rate.

As shown in Figure 2, SW2 is used

to set the protocol of communication and the baud rate used by the dome camera. DIP-4
to DIP-1 of SW2 is used to select protocols and 16 different protocols can be selected in
maximum. Following table shows states of coding switches of protocols selected by the
dome camera.