COP-USA CD66MK-HW User Manual

Page 18

Advertising
background image

- 15 -

3.4 Protocol and the Default Baud Rate

The SW2 is used to set the protocol of communication and the baud rate used by the dome

camera. DIP-4 to DIP-1 of SW2 is used to select protocols and 16 different protocols can be selected

in maximum. Following table shows states of coding switches of protocols selected by the dome

camera.

Protocols

DIP status

Normal Baud Rate

DIP-1

DIP-2

DIP-3

DIP-4

DIP-5

DIP-6

B01

ON

OFF

OFF

OFF

OFF

ON

SAMSUNG-1

ON

OFF

OFF

OFF

OFF

ON

Santachi

OFF

ON

OFF

OFF

OFF

ON

PELCO-P/D

ON

ON

OFF

OFF

OFF

OFF

PELCO-MK

OFF

OFF

ON

OFF

OFF

OFF

PANASONIC

ON

OFF

ON

OFF

OFF

ON

Longcomity

OFF

ON

ON

OFF

OFF

ON

HUNDA600

ON

ON

ON

OFF

OFF

ON

LILIN

OFF

OFF

OFF

ON

OFF

ON

VICON

ON

OFF

OFF

ON

ON

OFF

MOLYNX

OFF

ON

OFF

ON

OFF

ON

KALATEL

ON

ON

OFF

ON

ON

OFF

VCL

OFF

OFF

ON

ON

OFF

ON

SAMSUNG-2

ON

OFF

ON

ON

OFF

ON

ALEC

OFF

ON

ON

ON

OFF

ON

Ultrak

ON

ON

ON

ON

OFF

ON

Table 2

SAMSUNG-1 is old SAMSUNG protocol,SAMSUNG-2 is new updated SAMSUNG protocol.