Chapter 3

You must have sense jumpers or sense
lines installed to properly reference the
excitation voltage. To properly reference
a C2 calibration, run sense lines and
remove the sense jumper.

NOTE

When using load cells that do not have
sense lines, you will need to jumper the
Sense (-) to the Excitation (-) and the
Sense (+) to the Excitation (+) for one or
both channels.

Jumpers

RTA with jumpers for load cells without

sense lines

RTA Cable Assembly and Jumpers

A six-foot cable connects to the HI 1756 FC module.

RTA cable assembly - HI 1756WS

RTA cable schematic

Hardy HI 215IT Junction Box

Load
Cell
Connector

J1

1756 FC

Hardy HI 215IT Junction Box Wiring Diagram

NOTE

When connecting the Hardy HI 215IT Junction Box, you must remove the two factory
installed jumpers 1&2 and 5&6 on the module and install sense lines.