Hardy HI 1756-FC User Manual

Page 21

Advertising
background image


Third / Fifth Words - 2, 3, 4: Parameter Number and Value

The third and fourth words in the output table, Parameter Value, are used by the
WRITEPARAM command. The fifth word is the parameter ID, used by the
WRITEPARAM and READPARAM commands. Parameter values are written with the
least significant word first and one 32-bit integer per parameter. For details see the
Parameter Table below. Expanded descriptions are listed below the table by hex number.

All parameters are DINT.

There are 14 spare parameters for possible future use.

Notes

When set by a command, all parameters except the rate setpoint are saved to non-volatile
memory. Both rate and scale calibrations are saved automatically when completed
successfully. Totals are not saved automatically when changed, and will be lost if no
WRITENONVOLATILE command is executed before power down.

The section above “Format Word Decimal Point Parameters” explains Weight DP, Rate
DP, and Total DP, which appear in the chart below.

Parameters

#hex
/sub#

Brief Description (Note: Expanded descriptions are listed
below the chart by hexadecimal number)

Chan Active

1

0-1 flag, determines if a channel is alive.

Metric

2

0-1. Report Weight In. Units of measure listed below

span weight

3

Calibration weight, high. Must be >0. Weight DP.

cal low weight

4

Calibration weight, low. Must be > or = 0. Weight DP.

ROC time base

5

In seconds, 0 decimal places. 1-1800 seconds.

ROC time units

6

0=sec,1=min,2=hr

NumAverages

7

Dint. 1-255. Default = 1

WAVERSAVER 8

0-5 See 8 below

PID_P

9

1 decimal places.

PID_I

A

1 decimal places.

Batch amount

B

Weight DP. Must be > or = zero.

Preact

C

Weight DP. No limits.

Mode

D

15 // 0=continuous or 1=batch.

Prime Time

E

seconds, 0 decimal places.

Pause Time

F

seconds, 0 decimal places.

feed time

10

seconds, 0 decimal places.

Initial Refill on

11

0 = no, 1 = yes

Auto Refill On

12

0=off, 1=on

Refill Start
Weight

13

Weight DP. No limits

Refill End
Weight

14

Weight DP. No limits

Refill Too High
Weight

15

Weight DP. No limits.

Refill Shut
Down Weight

16

Weight DP. No limits.

Op Adjust

17

0=off,1= learning, 2= fixed.

Op Adjust %

18

6 decimal places.

Wait Time

19

Seconds, 0 decimal places. Must be > or = 0

16

Chapter 4