Hardy HI 1756-FC User Manual

Page 22

Advertising
background image


REC Level

1A

1 decimal place. Must be > or = 0.

REC Time

1B

Seconds, 0 decimal places. Must be > or = 0

REC Shutdown

1C

0=no, 1=yes

Shutoff Percent

1D

0 decimal places. 0-100

Total 1E

Total

DP

Batch Total

1F

Total DP. Must be > or = 0

Low Alarm Shut
Down Rate

20

Rate DP. No limits

High Alarm Shut
Down Rate

21

Rate DP. No limits

Alarm Delay

22

Seconds, 0 decimal places. Must be > or = 0.

Rate Setpoint

23

Rate DP. Must be > or = 0, < MAX RATE.

Rate Calibration Parameters See Rate Calibration Parameters section below

REC_P_Limit

1 decimal place. Must be > 0 and < or = 100.0.

7 Rate Cal Rates

(xx32)

7 rate calibration rates. All are R DP > or = 0.

0 rate

0032 0x0032 is the minimum rate

1st rate

1032 0x1032 is the next stepped rate

2nd rate

2032 0x2032 is the next stepped rate

3rd rate

3032 0x3032 is the next stepped rate

4th rate

4032 0x4032 is the next stepped rate

5th rate

5032 0x5032 is the next stepped rate

100 rate

6032 0x6032 is the MAX RATE

7 Rate Cal
Percentages

(xx33)

// 7 rate calibration percents. Uses 2 decimal places. 0.00-100.00

0 Percent

0033 0x0033 is the minimum %

1st Percent

1033 0x1033 is the next stepped %

2nd Percent

2033 0x2033 is the next stepped %

3rd Percent

3033 0x3033 is the next stepped %

4th Percent

4033 0x4033 is the next stepped %

5th Percent

5033 0x5033 is the next stepped %

100 Percent

6033 0x6033 is the MAX %

End Rate Cal section
ADC Average

34

0x0034 // Read Only

STATE

35

0x0035 // read only – see mode list below

Bit 0 Idle Mode

Bit 1 Auto Mode

Bit 2 Manual Mode

Bit 3 Start Mode

Bit 4 Stop Mode

Bit 5 Shut Off Mode

Bit 6 Pause Mode

Bit 7 Rate Cal Mode

Bit 8 Refill Mode

Bit 9 Full Mode

Bit 10 Manual Hold Mode

Bit 11 Rate Cal Hold Mode

17