Hardy Enviro Bench Scales User Manual

Page 17

Advertising
background image

Section 6: Serial I/O

12/09

12

0596-0315-01

Rev

B

Cust: Custom units. The display will indicate cust and the current selection, either y for enable or n for
disable. Press over/under/next, units or tare to change the selection. Press Program/Enter to enter the
selection.

Note: When custom units are active, units LED indicators are off in the weigh mode.

Azt: Programming the Automatic Zero Tracking band: (this feature will maintain zero when small amounts of
material are placed on the scale, such as rain, snow, debris, etc.) The display will indicate azt x where x is the
current setting. Press over/under/next, units or tare to change the selection. Press Program/Enter to enter
the selection. Available selections are:

OFF

Function is not active.

0.5

half of a division / increment / graduation

1

one division / increment / graduation

3

three divisions / increments / graduations

Bal: Programming the motion band (the range in divisions/increments/graduations that weight must be stable
before a print, zero, or tare function will be allowed). The display will indicate bal x where x is the current
setting. Press over/under/next, units or tare to change the selection. Press Program/Enter to enter the
selection. Available selections are:

OFF

Function is not active.

0.5

half of a division / increment / graduation

1

one division / increment / graduation

3

three divisions / increments / graduations


O.r: Programming the zero range: (the percentage of scale capacity that may be removed by pressing the Zero
Key). The display will indicate o.r x where x is the current setting. Press over/under/next, units or tare to
change the selection. Press Program/Enter to enter the selection. Available selections are:

100

100

percent

zero

range

2

2

percent

zero

range

D: Programming the division size: The display will indicate d followed by the current division size setting.
Press Over/Under/Next or units to scroll up, or tare to scroll down through the available choices. Press
Program/Enter to enter the selection. Available selections are:

50

20

10

5

2

1

0.5

0.2

0.1

0.05

0.02

0.01

0.005

0.002

0.001

0.0005

0.0002

0.0001

Filter: Programming the filter setting: (intended to minimize the effects of motion, vibration, and wind
currents) The display will indicate filter followed by the current filter setting. Press Over/Under/Next or
units to scroll up, or tare to scroll down through the available choices. Press Program/Enter to enter the
selection. Available selections are:

1 3 5 11

15

20

30

50


Flf: Flush filter factor: Allows indicator to switch to fast filter rate if weight change exceeds the number of
divisions in setting. The display will indicate flf followed by the current setting. Press Over/Under/Next or
units to scroll up, or tare to scroll down through the available choices. Press Program/Enter to enter the
selection. Available selections are:

oFF

1

2

5

10

20

50

100


Tare: Programming the tare setting: (the means by which a container’s weight may be removed, to set the
indicator to display the net weight only) The display will indicate tare followed by the current tare setting.

Advertising