4 service sealing, Commercial applications, Service sealing – Hardy Enviro Bench Scales User Manual

Page 25

Advertising
background image

Section 6: Serial I/O

12/09

20

0596-0315-01

Rev

B

5.4

Service Sealing

Commercial Applications

Scales used in a commercial application must be “placed in service” in accordance to local weights and
measures
guidelines.

Four sealing screws are provided on the back cover to allow a lead seal to be installed if required.

An audit trail is provided to track changes in programming and calibration. Access to the audit trail is as
follows:

1. Press and hold b/g / net for approximately 10 seconds.

2. Indicator will display cfgctr. This is for the configuration audit.

3. Press Over/Under/Next to toggle to calctr. This is for the calibration audit. Repeated pressing of

this button will toggle between the two choices.

4. At either prompt, cfgctr or calctr, press program/enter. This will display the audit counter for that

particular audit trail.

5. If connected to a printer, print may be pressed at this time to print both audit trail counters.

6. Press Program/Enter again to return to cfgctr or calctr. Both audit trails can be viewed without

returning to the weigh mode.

7. When finished viewing audit trails, press units to return to normal weighing.

Advertising