7.1. BASIC SCALE OPERATIONS

Upon power up the Indicator performs a warm-up cycle.

 The Indicator initiates a test, displaying numbers

1

to

8

, and lights up all LED’s.

 The Program number and Revision Information displays.
 The Indicator then displays the current weight on the scale

7.2. KEYPAD FUNCTIONS, WEIGH MODE

KEY

ACTION

Recipe 1-4

Enables or disables programmed recipe in Checkweigh mode.

 In peak weigh mode, 1 enables peak, 2 disables, and 3 resets peak.

TARE

Automatically tares off the displayed weight.

 If held for 3 seconds, enables or disables accumulate function.

ZERO

Resets gross weight to center of zero.

PROGRAM/ENTER

Captures weight and adds to accumulation if enabled.

OVER/UNDER/NEXT

Displays accumulated weight and number of weighments if enabled.

 If held for 3 seconds, enters Checkweigh or peak weight setup.

UNITS

Switches between selected weighting units.

B/G – NET

Toggles between gross and net weights.

 If held for 10 seconds, displays audit trail functions.

PRINT

Transmits transaction data out com port 1 if button is selected.

7.3. INSTRUMENT WEIGHING FUNCTIONS

Basic Weighing

Ensure that the bench scale is empty, power on the indicator, press the zero key and the display indicates “0”
and is ready for use.

Gross Weighing

1. Press the b/g / net key, if required, to set the display to GR (gross).

2. Press the zero key, if required, to set scale to “0.”

3. Place container/object on the scale platform.

4. Read the gross weight on the display.

Net Weighing

1. Press the b/g / net key, if required, to set display to GR (gross).

2. Press the zero key, if required, to set scale to “0.”