Clarion UNGO MS8200 User Manual

Page 13

Advertising
background image

3-Pin Door Lock Harness

Pin 1 - WHITE/green: Door Lock (-) / Door Unlock (+)
Pin 2 - **not used**
Pin 3 - WHITE/blue: Door Unlock (-) / Door Lock (+)

These wires can be directly connected to negative and positive triggered door lock systems.
For Voltage Reversal systems and After-market actuators, add relays. For further
information, see

Door Lock Diagrams. For selection of Double Pulse output, Comfort

Closure, and 4-second pulse, see

Programming and Jumper and Switch Settings.

4-Pin Optional Sensor Harness

Pin 1 - RED: +12v output.

Provides +12v to power optional sensor. Do not connect this wire to anything other than an
optional sensor or the Space Shield III, included with the MS8300.

Pin 2 - WHITE

or WHITE/orange: Armed (-) output.

Provides ground to turn on the optional sensor only when the system is Armed.

Pin 3 - WHITE/violet: Optional Sensor (-) trigger input.

Connect to the negative trigger output from an optional sensor.

Pin 4 - VIOLET/ yellow: Warn Away (-) input.

Connect to the negative Warn Away output from an optional sensor.

Other Harnesses

For details on the Status LED and Override Switch, see

Mounting Components.

Extra LEDs

Up to 3 extra LEDs can be added. Cut the Red LED wire and connect in series as shown.

MS8200 / MS8300 Installation Manual - Page 11

LED

Connector

installation_rev3.qxd 7/26/99 6:07 PM Page 11

Advertising
This manual is related to the following products: