Logic sensor ii – Clarion UNGO MS8200 User Manual

Page 23

Advertising
background image

MS8200 / MS8300 Installation Manual - Page 21

Because of its advanced design, the Logic Sensor II can be set for Shock and Motion
detection or Shock detection only, simply by the way the sensor is mounted. See

Mounting

Components.

Adjustment

The shock and motion sensitivity of the Logic Sensor II are set independently, using the Remote
Transmitter. For shock, there are 12 levels of sensitivity. For motion, there are 8 levels of
sensitivity. Level 1 is off for both shock and motion.

• If the motion sensitivity is set to Level 1, the Logic Sensor II will not detect motion, only shock.
• If the shock sensitivity is set to Level 1, the Logic Sensor II will not detect shock, only motion.
• If

both shock and motion are set to Level 1, the Logic Sensor II will be completely off.

When both shock and motion sensitivity are set to Level 1, the siren will emit 1 chirp, followed by 3 chirps each
time the system is Armed to indicate that the Logic Sensor II is off.

To Adjust the sensitivity:

1. Turn the ignition key on.
2. Within 4 seconds, press Transmitter Button 1.

• The siren will chirp (1 through 12) to indicate the current shock sensitivity level. The

default shock sensitivity setting is 6.

3. Test the sensitivity. The siren will respond with a short chirp when shock is detected

and a long chirp when motion is detected.

• The Logic Sensor II has 8 levels of sensitivity for motion. The default motion

sensitivity setting is 4.

Be sure that the Logic Sensor II is mounted horizontally if motion detection is desired.

4. To make adjustments:

Press Button 1 to increase the

shock sensitivity.

Press Button 2 to decrease the

shock sensitivity.

Press the Mode Button, then Button 1 to increase the

motion sensitivity.

Press the Mode Button, then Button 2 to decrease the

motion sensitivity.

• The siren will chirp to indicate the sensitivity level each time the Button is pressed.

5. When you are satisfied with the sensitivity, turn off the ignition.

Warn Away Sensitivity

Logic Sensor II

Logic Sensor II Sensitivity

Shock Level

Motion Level

1 2

12

off lowest

highest

1 2

8

off lowest

highest