Page 22 - MS8200 / MS8300 Installation Manual

The Space Shield III is a dual zone proximity sensor that uses high frequency radar signals to
detect the presence of moving objects within a defined area. For more information, see
Mounting Components.

Operation

While the system is armed, each time the Space Shield III detects movement in the Exterior
zone, the siren will emit a warning chirp. When movement is detected in the Interior zone, the
system will trigger.

The Space Shield III can be set to operate in one of two ways: with and without Perimeter Alarm.
To select the Operating Mode of the Space Shield III, see

Programming - Step 8, Radar Sensor

Warn Away Trigger.

With Perimeter Alarm

When movement is detected in the Exterior zone 3 times, within 15 seconds, the system will
trigger.

Without Perimeter Alarm

Detected movement in the Exterior zone will cause the siren to emit a warning chirp. Only
movement in the Interior zone will trigger the system.

Adjustment

To Enter Space Shield III Adjustment,

1. Turn on the ignition.
2. Within 4 seconds, press the Mode Button twice, then Button 1.

• The siren will emit one chirp.
• The radar sensor will turn on and perform a system check. (This will take

approximately 15 seconds.)

• When the sensor is ready, the siren will chirp 3 times and the Interior zone can be

adjusted.

3. Test the Interior zone sensitivity.

• Each time the sensor detects movement, the siren will chirp 1 time and the LED on

the sensor will light red.

4. To make adjustments:

Press Button 1 to increase the sensitivity.
Press Button 2 to decrease the sensitivity.

• The siren will emit one long chirp when the sensitivity is

increased and two long

chirps when the sensitivity is

decreased.

Space Shield III

The sensitivity of the Logic Sensor II’s Light Impact Response can also be adjusted. There
are two settings for Warn Away, High and Low. The default setting is High. To change the
setting, see

Programming.