10. Auxiliary Function 2 - Momentary / Latched / Timed Operation. (resets with arm and

disarm) Selects between Momentary, Latched, or Timed output for Aux. 2.

When

Momentary operation is selected, the system will provide an output for as long as

the Transmitter button is held.

When

Latched operation is selected, the system will provide an output that turns on when

the transmitter button is pressed and turns off when the transmitter button is pressed again.

When

Timed operation is selected, the system will provide an output that turns on for 30

seconds each time the transmitter button is pressed. If the button is pressed again during
the 30 seconds, the output will turn off.

When the Latched or Timed outputs are activated:

• Arming the system will turn off the Aux. 2 output if it was turned on while the system was

disarmed.

• Disarming the system will turn off the Aux. 2 output if it was turned on while the system

was armed.

11. Auxiliary Function 3 - Momentary / Latched / Timed Operation. Selects between

Momentary, Latched, or Timed output for Aux. 3.

When

Momentary operation is selected, the system will provide an output for as long as the

Transmitter button is held.

When

Latched operation is selected, the system will provide an output that turns on when

the transmitter button is pressed and turns off when the transmitter button is pressed again.

When

Timed operation is selected, the system will provide an output that turns on for 30

seconds each time the transmitter button is pressed. If the button is pressed again during
the 30 seconds, the output will turn off.

The operation of Aux. 3 is

not affected by arming and disarming.