Clarion UNGO MS8200 User Manual

Page 27

Advertising
background image

MS8200 / MS8300 Installation Manual - Page 25

• During output testing, each function will stay active for as long as the transmitter

button is held.

After you have finished testing, turn off the ignition key to exit Real Time Installation
Verification.

Starter Defeat

Override Switch

Sensor Kill Wire

Hood/Trunk Input

Door

Optional Sensor Input

Warn Away Input

Door Closed Door Open

Function To Test

Response

Turn Key To Start Position

Press Override Switch

Ground Gray/black wire

Open Hood/Trunk

Open Door

Trigger Optional Sensor

Trigger Warn Away input

Vehicle will not start

LED Flashing

LED Solid

4 Chirps

1 Chirp

3 Quick Chirps
2 Quick Chirps

Input Test

Parking Lights

Dome Light

Door lock

Door unlock

Horn

Siren

Function To Test

Button 1
Button 2

Mode, 2

Mode, Mode, 1
Mode, Mode, 2

Mode, Mode, Mode, 1

Output Test

Any T

ime

installation_rev3.qxd 7/26/99 6:07 PM Page 25