Chapter 6. Calibration

6-1

Chapter 6. Calibration

Introduction

The Cal Menu is used to set up and calibrate
the Weigh II with the sensors wired to the
Weigh II (for example, L-Cells, Microcells,
Load Stand II, Load Disc II, and Load Link).
This chapter covers the functions in the Cal
Menu. Explanations of each of the functions
are provided. Additionally, detailed navigation
procedures through the menu tree are
provided for each type of calibration.

As shown in Figure 6-1, the Cal Menu has
three submenus, described below.

1. Auto — used to set the lo span, hi span,

and zero calibration values while moving
material into or out of the vessel.

2. Manual — used to manually set the scale

factor counts, scale factor weight, and
zero counts. Use manual calibration to
pre-calibrate the system, fine-tune the
calibration, or re-enter previous
calibration data.

3. Linear — used to set up and turn on and

off the linearization table. Use of this
function may be required if your vessel’s
structure responds non-linearly, but
consistently, to changes in load,
resulting in consistent, incorrect weight
readings after the system has been
correctly calibrated.

Auto

There are three different methods for perform-
ing automatic calibration:

• High-Accuracy Calibration
• Calibration by Adding a Known Quantity of

Material

• Calibration by Subtracting a Known

Quantity of Material

The latter two methods do not provide as high
accuracy calibration as the first method.
However, these lower accuracy calibrations
can be later refined to increase the accuracy
(see the topic Refining the Calibration by
Setting Zero
in this section).

Note

See Appendix H, Error Messages, for
an explanation of error messages you
may encounter while performing an
Auto Calibration.

Auto

Manual

Linear

Cal

On

Off

Set

ScfCnt

ScfWgt

Zero_Cnt

Disply

Reset

LoSpan

HiSpan

Zero_Cal

Disply

Reset

Figure 6-1. The Calibration Menu Tree