Chapter 6. Calibration

6-11

8. Press the F3 Key to access the Set

Menu. The display looks like this:

9. Use the keypad or the Up and Down Arrow

Keys to enter a new value for the Raw
Input
. Press the Enter Key to save the
new value in memory. The display then
switches to a display that looks
like this:

10.

Use the keypad or the Up and Down

Arrow Keys to enter a new value for the
Corrected Output. Press the Enter Key to
save the new value in memory. The display
then switches to a display that looks like
this:

11.

Repeat Steps 9 and 10 as desired

until you have completed your setup of the
linearization table.

12.

Press the Esc Key to scroll up the

menu tree or press the Auto/Man Key to
return the display to vessel monitoring.

Indicated
Weight

Counts

○○○

○○○○○○○○

○○○○○○○○

○○○○○

Non-Linear
Input

1R
1C

2C

2R

4R

3R 4C

5R
5C

○○○○○○○○○○○○

○○○○○

Linearized
Output

Figure 6-4. Linearization Curve

Pt RAW INPUT

01> 1048576 Cnts

F1 F2 F3

Pt CORRECTED OUT

01> 1048576 Cnts

F1 F2 F3

Pt RAW INPUT

02> 1112576 Cnts

F1 F2 F3

Linearizing Table

Raw Input

Corrected Output

1R

1C

2R

2C

3R

3C

4R

4C

5R

5C

Requirements of table values:
1R<2R<3R<4R<5R
1C<2C<3C<4C<5C
1R=1C
5R=5C

3C