Examples, Command — km product identification number, W’ command — engineering units (gross) – Kistler-Morse KM Weigh II User Manual

Page 74: B’ command — engineering units (net), T’ command — tare addressed vessel, U1’ command — request raw counts

Advertising
background image

Appendix C. Seral Comments

C-4

Examples

For each command below, the general format of the command is shown above the example.

‘#’ Command — KM Product Identification Number

This command is sent by the master to request the Weigh II to send its KM product identification
code (code is 80 for the Weigh II). For this example, the master requests the code from a Weigh II
channel at address 01, which returns a code of 80 and a checksum of 68.

Request from Master

Response from Weigh II

>aa#ssr

Addssr

Format

>01#84r

A8068r

Example

‘W’ Command — Engineering Units (gross)

This command is sent by the master to request the Weigh II to send the gross engineering units
(weight, level, etc.). For this example, the master requests the gross weight from a Weigh II channel
at address 01, which returns a gross weight of +7103 and a checksum of 86.

Request from Master

Response from Weigh II

>aaWssr

A±dddddddssr

Format

>01WB8r

A+000710386r

Example

‘B’ Command — Engineering Units (net)

This command is sent by the master to request the Weigh II to send the net engineering units
(weight, level, etc). For this example, the master requests the net weight from a Weigh II channel at
address 01, which returns a net weight of -4466 and a checksum of 91.

Request from Master

Response from Weigh II

>aaBssr

A±dddddddssr

Format

>01BA3r

A-000446691r

Example

‘T’ Command — Tare Addressed Vessel

This command is sent by the master to request the Weigh II to tare the indicated vessel. For this
example, the master requests the tare for a Weigh II channel at address 01.

Request from Master

Response from Weigh II

>aaTssr

Ar

Format

>01TB5r

Ar

Example

‘u1’ Command — Request Raw Counts

This command is sent by the master to request the Weigh II to send the raw counts. For this
example, the master requests the raw counts from a Weigh II channel at address 01, which returns
a raw count of 1147226 and a checksum of 67.

Request from Master

Response from Weigh II

>aau1ssr

Adddddddssr

Format

>01u107r

A114722667r

Example