Chapter 6. Calibration

Manual

For manual calibration, you calculate and
input directly the slope and setting zero
points of the calibration line. There are three
reasons for doing a manual calibration
instead of an automatic calibration:

• You cannot move any material now, and

want to get started using your system with
a rough pre-calibration.

• You calibrated the system. Later, you

moved material into an empty vessel and
kept an accurate record of the actual
material weight (based on a truck weight or
some other accurate information) and the
indicated material weight (from the Weigh
II). However, you did not perform a calibra-
tion procedure at the time. You want to
use this information now to refine the
calibration.

• You want to re-enter data from a previous

calibration.

The calculation of the manual calibration
parameters for both a pre-calibration and for
calibration refining is covered in Appendix G,
Calculation of Manual Calibration Parameters.
Once you have calculated the parameters,
follow the procedure below to perform a
manual calibration.

1. If the Weigh II is in Auto Mode (Auto LED

illuminated), press the Auto/Man Key to
put the system in Manual Mode. The Auto
LED turns off.

2. Use the Up Arrow and Down Arrow Keys to

scroll to the desired vessel.

3. Press the Menu Key to display the Main

Menu. The display shows:

4. Press the F3 Key to access the Cal Menu.

The display shows:

5. Press the F3 Key to access the Manual

Menu. The display shows:

6. Press the F1 Key to access ScfCnt. The

display looks like this:

7. Use the keypad or the Up and Down Arrow

Keys to input a value for the scale factor
counts. Press the Enter Key to save the
value in memory. The display flashes a
message acknowledging your entry and
returns to:

8. Press the F3 Key to access ScfWgt. The

display looks like this:

The unit of measure you set up in the
Units Menu shows in place of lbs.

9. Use the keypad or the Up and Down Arrow

Keys to input a value for the scale factor
weight. Press the Enter Key to save the
value in memory. The display flashes a
message acknowledging your entry and
returns to:

10.

Press the Menu Key to go to the

second page of the Manual Cal Menu. The
display shows:

11.

Press the F1 Key to access

Zero_Cnt. The display looks like this:

CALIBRATION MENU

Auto Manual

F1 F2 F3

MANUAL CAL MENU

ScfCnt ScfWgt

F1 F2 F3

WII MAIN MENU

Disp I/O Cal

F1 F2 F3

SCALE FACTOR

> X counts

F1 F2 F3

MANUAL CAL MENU

ScfCnt ScfWgt

F1 F2 F3

SCALE FACTOR

> X lbs

F1 F2 F3

ZERO CALIBRATE

> X counts

F1 F2 F3

MANUAL CAL MENU

Zero_Cnt Disply

F1 F2 F3

MANUAL CAL MENU

ScfCnt ScfWgt