Sf/sg series operating instructions – A&D Weighing SG-30KA User Manual

Page 13

Advertising
background image

SF/SG Series Operating Instructions

F1: Auto display off

0: Yes

1: No

F2: Cancellation of unit price 0: Selectable

1: No 2: Yes

F3: Output Data

0: Key trigger mode 1

1: Key trigger mode 2

(Refer to the note below.) 2: Command mode

3: Stream mode

4: Key trigger mode 3 with delay
5: Key trigger mode 3 without delay
6: Not used

7: Not used

8: Label printer mode

F4: Baud Rate

0: 600 bps

1: 1200 bps

2: 2400 bps

3: 4800 bps 4: 9600 bps

F5: Parity Bit

0: 7 bits (Even)

1: 8 bits (No parity)

F6 and F7: Not used

Normally F6=0, F7=1

12

Note:

A scale that has totaling and multiplier functions can use F3 = 4 or 5.

F3=8 is used when the SF/SG scale is connected to an AD-8124 label printer.