Aerco, Appendix g, Piping diagrams – AERCO BMK 2.0 LN Dual Fuel Nov 2010 User Manual

Page 115: Le ge n d

Advertising
background image

APPENDIX G

G-5

PIPING DIAGRAMS

H

E

AT

ING

SYSTE

M

RET

URN F

ROM

SU

PP

L

Y

T

O

D

O

M

E

S

T

IC

ST

OR

A

G

E GENERAT

O

R COIL

M

O

TO

R

IZE

D

G

L

O

BE

VAL

VE

P&T

P&T

P&T

SU

PP

L

Y

TO

HEA

T

ING

SYST

EM

BACKF

L

O

W

PREVENTE

R

LIN

E

S

IZ

E

BYPA

SS

SY

STEM

M

AKE

-U

P

WA

T

E

R

SUPP

L

Y

T

Y

P

ICAL

L

O

CAT

ION OF

M

A

K

E

UP AND

EX

PANSIO

N

CO

M

PO

N

EN

T

S

P

R

ESS. RED.

FIL

L

VAL

VE

D

IAPHRAG

M

TYPE

EXP

ANSIO

N

TA

N

K

A

A

B

E

NC

HM

ARK 2

.0

M

IL

. B

T

U G

AS FI

RED

BO

IL

ER L

AYO

UT

FO

R CO

M

BINAT

IO

N

HEAT

ING

& DO

M

ESTI

C

WATE

R

PL

A

N

T

1

) F

O

R

ACT

U

AL

SIZ

ES AND L

O

CAT

IO

N

S

OF

PIP

ING AND OT

HER CONNECT

IO

NS T

O

T

H

E

BO

IL

ER, S

EE DIM

E

NSIONAL

EL

ECTRIC

CO

NN

ECTIONS (S

ERVICE SW

IT

CHES,

CO

NDUIT

BOXES)

S

H

O

U

L

D

L

IK

EW

ISE

BE 6

"

AW

AY FR

O

M

SI

D

E

PANEL

S

.

4)

L

O

CAT

E

WAT

E

R

INL

E

T AND O

U

TLE

T

F

ITT

ING

S

(

i.e.

UNI

O

N

S, E

L

BO

WS,

ETC.)

A M

INIM

U

M

O

F

6''

FRO

M

BO

IL

ER

A H

E

IG

H

T

1

8

'' AB

O

V

E

FL

O

O

R

.

2

)

SHEL

L

DR

A

IN VAL

VE AND CO

NDENSAT

E DRAIN TR

A

P

SHO

U

L

D

BE

ARRANG

ED TO

PERM

IT

THE F

L

UIDS TO

DR

A

IN

5

) T

H

IS

IS A

T

YPI

C

A

L

INST

A

L

L

A

T

ION DRAW

IN

G

. L

O

CAL

CO

DES

AND AUT

H

O

R

IT

IES

S

H

O

U

L

D

BE CONSUL

T

E

D.

3

) AL

L

(*) IT

EM

S

ARE I

N

CL

UDED SEPARAT

EL

Y I

N

SHIPM

ENT F

R

O

M

FACTO

R

Y.

NO

TES:

A

IR SEPARAT

O

R

RET

U

R

N

F

R

O

M

DO

M

E

STIC STO

R

A

G

E

GENERAT

O

R C

O

IL

REL

IEF

VAL

VE

(T

YP.

)

CHECK VAL

VE

(TY

P

.)

DRAWING

(

A

P-

A-8

7

4

).

F

R

E

E

L

Y

, BY G

R

AVITY

, TO

A

CO

N

V

EN

IENT FL

O

O

R

DRAIN. RE

L

IEF

VAL

V

ES SHO

U

L

D

BE

PIPED

VERTICAL

L

Y TO

A

FITT

ING

S

T

O

P

R

E

VENT INT

E

RFERENCE W

ITH

REM

O

VAL

O

F

BO

IL

E

R

PANEL

S AND CO

VERS.

AL

L

PIPI

N

G

AND

N

O

R

T

H

VAL

E,

N

J

0

7

6

4

7

IN

TE

RN

AT

IO

NA

L

, I

N

C.

AP

PD

.

DW

N.

B

Y

SC

A

L

E

DA

T

E

MPC

0528

98

DA

T

E

SC

D

NT

S

0526

98

AERCO

SD

-A

-8

21

A

RE

V

.

TEM

PERATURE G

AUG

E

P&T

PRESSURE &

BAL

ANCING

VAL

VE

ISO

L

AT

IO

N VA

LVE

FLAN

G

E

Y-STRAINER

LE

GE

N

D

PUM

P

BM

S H

E

A

D

ER

TEM

P

. SENSO

R

Advertising