Table 1: acm/16/flex16/16rj address settings, Table 1: acm/16/flex16/16rj address settings -5, Warning – Connect Tech NT960/PCI User Manual

Page 35

Advertising
background image

Chapter 2: Hardware Installation

2-5

Intellicon-NT960/PCI User's Manual, ver. 0.02

WARNING

Do not use a pencil to set the DIP switches as the lead graphite
may short-circuit the switch.


Table 1:
ACM/16/Flex16/16RJ address settings

Address

Port numbers
assigned

ACM/16RJ
Switch settings

ACM/16/Flex16
DIP Switch settings

1

2

3

1

1 - 16

1

on

on

on

2

17 - 32

2

off

on

on

3

33 - 48

3

on

off

on

4

49 - 64

4

off

off

on

5

65 - 80

5

on

on

off

6

81 - 96

6

off

on

off

7

97 - 112

7

on

off

off

8

113 - 128

8

off

off

off

Example:
The following examples show the ACM/16, ACM/Flex16 or
ACM/16RJ address switch block or switch set for:

Address 1, ports 1 through 16(default):

Address

0

1

ACM/16/Flex16

Address

1

2

3

4

5

6

7

8

ACM/16RJ


Address 2, ports 17 through 32:


Address

0

1

ACM/16/Flex16

Address

1

2

3

4

5

6

7

8

ACM/16RJ