Chapter 4: Appendix D - RS-485/422 Option

4-19

Intellicon-NT960/PCI User's Manual, ver. 0.02

Switch positions 5 and 6 on switch blocks S1, S2, S3, and S4
allow the "receiver stations" (RxD and CTS) to have either a DC
load
of 150 ohms or an AC load of 150 ohms in series with a 50
nF capacitor. Please refer to the examples following for these
configuration options and their switch settings.


Examples:
1. The following example shows the switch settings for Station A

as per Figure 17 where TxD and RTS have a load of 150

.

switch blocks

S1, S2, S3, or S4


2. The following example shows the switch settings for Station B

and Station C as per Figure 17.

switch blocks

S1, S2, S3, or S4

3. The following example shows the switch settings for Station

D as per Figure 17 where RxD and CTS have a DC load of
150

..

switch blocks

S1, S2, S3, or S4


4. The following example shows the switch settings for Station

D as per Figure 17 where the circuit is > than 50 metres in
length and RxD and CTS have an AC load of 150

in series

with 50 nF.

switch blocks

S1, S2, S3, or S4