Operating environment, Power requirements, Dimensions – Connect Tech NT960/PCI User Manual
Page 54: Operating environment -2, Power requirements -2, Dimensions -2
4-2
Chapter 4: Appendix A - Specifications
Intellicon-NT960/PCI User's Manual, ver. 0.02
ACM/Flex16
Four CLCD1400 RISC like quad UARTs with 12 bytes of
FIFO per channel on the chip
EIA RS232-C and/or RS485/422 Interface and/or 20mA
Current Loop
Sixteen RS-232 and/or RS-485/422 and/or 20mA Current
Loop asynchronous ports with male DB-9 connectors
Ports configurable from 50 up to 115 Kbps
Programmable Baud Rate Generator
ACM/16RJ
Four Cirrus Logic
CD1400 RISC like quad UARTs with 24
bytes of FIFO per channel on the chip
EIA
RS232-C
Interface
Sixteen RS-232 asynchronous ports with RJ-45 connectors
Ports configurable from 50 up to 115 Kbps
Programmable Baud Rate Generator
Operating Environment
ACM/16, ACM/Flex16 and ACM/16RJ
Ambient temperature:
0 - 70
° C
Relative humidity:
0 - 90% no condensing
Air
movement:
no
requirement
Altitude:
15,000
feet
(5,000
metres)
Power Requirements
ACM/16, ACM/Flex16 and ACM/16RJ
Power
supply
provided
Dimensions
ACM/16
Length: 32.812
cm
Width: 11.562
cm
Height: 4.062
cm
ACM/Flex16
Length: 32.812
cm
Width: 14.100
cm
Height: 4.062
cm
ACM/16RJ
Length: 32.85
cm
Width: 11.55
cm
Height: 4.84
cm