Operating environment, Power requirements, Dimensions – Connect Tech NT960/PCI User Manual

Page 54: Operating environment -2, Power requirements -2, Dimensions -2

Advertising
background image

4-2

Chapter 4: Appendix A - Specifications

Intellicon-NT960/PCI User's Manual, ver. 0.02

ACM/Flex16

„

Four CLCD1400 RISC like quad UARTs with 12 bytes of

FIFO per channel on the chip

„

EIA RS232-C and/or RS485/422 Interface and/or 20mA

Current Loop

„

Sixteen RS-232 and/or RS-485/422 and/or 20mA Current

Loop asynchronous ports with male DB-9 connectors

„

Ports configurable from 50 up to 115 Kbps

„

Programmable Baud Rate Generator

ACM/16RJ

„

Four Cirrus Logic

 CD1400 RISC like quad UARTs with 24

bytes of FIFO per channel on the chip

„

EIA

RS232-C

Interface

„

Sixteen RS-232 asynchronous ports with RJ-45 connectors

„

Ports configurable from 50 up to 115 Kbps

„

Programmable Baud Rate Generator


Operating Environment

ACM/16, ACM/Flex16 and ACM/16RJ

„

Ambient temperature:

0 - 70

° C

„

Relative humidity:

0 - 90% no condensing

„

Air

movement:

no

requirement

„

Altitude:

15,000

feet

(5,000

metres)

Power Requirements

ACM/16, ACM/Flex16 and ACM/16RJ

„

Power

supply

provided

Dimensions

ACM/16

„

Length: 32.812

cm

„

Width: 11.562

cm

„

Height: 4.062

cm

ACM/Flex16

„

Length: 32.812

cm

„

Width: 14.100

cm

„

Height: 4.062

cm

ACM/16RJ

„

Length: 32.85

cm

„

Width: 11.55

cm

„

Height: 4.84

cm