Appendix G: Factory Settings

This section summarizes the factory settings for the following
Intellicon-NT960/PCI hardware components:

„

Intellicon-NT960/PCI

Host

Adapter

„

Intellicon-NT960/PCI ACM/16, ACM/16RJ and

ACM/Flex16

„

ACM/Flex16 RS-485 SLIM

WARNING

Do not use a pencil to set the DIP switches as the lead graphite
may short-circuit the switch.

Your Intellicon-NT960/PCI adapter, ACM/Flex16 and Serial Line
Interface Module (SLIM) are very sensitive to static electricity.
Make sure that before you remove them from the anti-static
shipping bag, you wear an anti-static wristband. When you
remove them from the anti-static bag, handle them only by the
edges and place them on the anti-static bag or an anti-static mat.

NT960/PCI Host Adapter

The NT960/PCI Host Adapter ships with factory settings for the
following:


Table 9: NT960/PCI SW1 factory settings

Switch Position Configuration

ON

1 2 3 4 5 6

SW1

Switch 6 on DIP switch block SW1 set

on

.

One to 8 ACM modules stacked together,
with only one bus cable between the
NT960/PCI Host adapter and the first ACM
module.

Note:
Switches 1 through 5 are set off and must not be changed.