CAMCORP CAM-AIRO Vertical Cartridge User Manual

Page 19

Advertising
background image

CAMCORP, INC.

Phone: 913-831-0740 Fax: 913-831-9271

www.camcorpinc.com

Section 4 - Operation

, 01

(

0

,5

A. Solids laden air or gases enter the unit at the hopper or housing inlet.

B. Air passes through the filter media.

C. Solids are retained on the filter media surface.

D. Cleaning cycle consists of a momentary blast of 80-90 psig compressed

air:

1.

Momentarily taking a row of cartridges off stream through

pressure reversal.

2.

Flexing filter cartridge media.

3.

Solids are released to fall towards hopper and through rotary

valve or other discharge equipment.

4-1