Specifications – Installation and Operating Instructions

BULLETIN E-97

Series DCT1000 Dust Collector Timer Controller

Thank you for purchasing the DCT1000 Dust Collector Timer
Controller. You have selected a state of the art dust collector
timer control that will provide years of dependable operation
and service.

The DCT1000 Dust Collector Timer Controller was designed
to be used with pulse-jet type dust collectors for on-demand
or continuous cleaning applications. The DCT1000 consists
of three basic modules: the master controller, the optional
channel expander (slave board) and the pressure module
(DCP100/200). This manual is limited to the installation and
operation of the master controller and optional channel
expander. For installation requirements on the pressure mod-
ule, please refer to the installation and operating instructions
for the DCP100/200.
Continuous cleaning applications do not require external
inputs and can be used for time based “on-demand” clean-
ing through use of the cycle delay feature.
For on-demand applications, the plug-in pressure modules
(DCP100/200) can be used to take full advantage of all the
features the DCT1000 offers, or an external pressure switch
(such as the Dwyer Photohelic

®

) can be used for High/Low

limit control.

As with traditional Dwyer products, the Dwyer DCT1000 was
designed so that it is easy to use, thus allowing for a quick
and easy start up for your dust control applications. The con-
tents inside this installation and operating manual will guide
you through the features of the DCT1000 and how they can
be applied to get the most out of your dust control require-
ments.

DWYER INSTRUMENTS, INC.

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361 U.S.A.

PHYSICAL DATA
Storage Temperature:
-40˚F to 176˚F (-40˚C to 80˚C).
Operating Ambient Temperature: -40˚F to 140˚F (-40˚C to
60˚C).
Weight: 1 lb. 3.0 oz. (538.6 grams).
Power: 50 or 60 Hz, 85 to 270 VAC input.
Power input: 270 VAC RMS max., transients: 80 Joule @
1000 msec/50 Joule @ 2 msec.
Fuse: 3A @ 250 VAC.
Low voltage control circuitry is isolated from the line voltage for
system safety.
Output Channels: up to 22 on one module, expandable to
255 using additional expansion modules.
Solenoid supply: 300 VA max.
On-time: 10 msec to 600 msec, 10 msec steps.
On-time Accuracy: ±10 msec.
Off-time: 1 to 255 seconds, in 1 second steps.
Off-time Accuracy: ±1% of the value or ±50 msec, which
ever is greater.

Default Settings:
Channels:
All installed channels
Time-off: 10 seconds
Time-on: 100 msec.
Down-time Cycles: 1 minute
Cycle Delay: 0 minutes.
Low Alarm: 1.0

w.c. [0.25 kPa]

High Alarm: 6.0

w.c. [1.49 kPa]

Low Limit: 3.0

w.c. [0.75 kPa]

High Limit: 5.0

w.c. [1.24 kPa]

Auto Alarm Reset: 5 seconds.