CAMCORP CAM-AIRO Vertical Cartridge User Manual

Page 20

Advertising
background image

CAMCORP, INC.

Phone: 913-831-0740 Fax: 913-831-9271

www.camcorpinc.com

10 !,

)

65.

Installation

Make sure the unit is secured to the floor or mounting surface. The

ladder(s) and platform(s) must be tightened and set up according to

OSHA requirements. Ducting and piping must be secured and routed out

of the way of traffic whenever possible to avoid injury. Ducting must also

be free of all debris including moisture.

Interior of Dirty Air Plenum

Inspect the filter cartridges, referring to the “Filter Cartridge Installation”

section of this manual. Improperly installed cartridges may allow dusty air

to enter the clean air plenum.

Exterior of Dust Collector

Access doors, inspection ports and spring-loaded relief vents should seat

effectively to prevent leakage.

All bolts must be properly tightened.

Operate any equipment connected to the dust discharge of the dust

collector. Check the rotation of any motor driven equipment such as

rotary airlocks, horizontal unloading valves, live bottom bin activators and

screw conveyors. Check slide gates and butterfly valves for binding

.

4-2

Advertising