Infinet™ thermostat crestron chv-tstatrf – Crestron electronic CHV-TSTATRF User Manual

Page 16

Advertising
background image

infiNET™ Thermostat

Crestron CHV-TSTATRF

CHV-TSTATRF in Cool Only Application

(Refer to “Basic Thermostat

Setup” on page 15)

Optional, for power

Transformer

R

C

C

Y

G

R

Compressor

Relay

Fan

Relay

RH-RC jumper required
since supply power is
returned through RH

CHV-TSTATRF in Heat-Cool Application with Separate Systems

C

W

R

Y

R

Compressor

Relay

Transformer

R

C

Cooling

Transformer

R

C

Heating

Heat

Relay

G

Fan

Relay

(Refer to “Basic Thermostat

Setup” on page 15)

Optional, for power

12

infiNET™ Thermostat: CHV-TSTATRF

Operations & Installation Guide – DOC. 6490A