SECTION 5

SERVICE TECH INFORMATION

5C. WATER FLOW THROUGH THE SOFTENER VALVE

BRINING AND BRINE RINSE CYCLES

bypass hard water

to valve outlet

venturi

nozzle

brine from

salt stor­
age tank

\ drain

from Valve Inlet

(hard water)

After fill, timer/switch aaion allows the motor to turn the rotor and disc into

BRINING position. Water flow is direaed to the nozzle. Suction, created by the
nozzle and venturi, draws brine from the salt storage tank and injects it into the resin
bed via the bottom distributor. Flow continues out the top distributor and to the
drain. Hard water is available at the valve outlet.

When the brine valve closes to end brine draw, water flow continues in the same
directions to slowly RINSE brine from the resin bed and to the drain.

BACKWASH CYCLE

Timer/switch action again allows the motor to turn the
rotor & disc to place the valve in BACKWASH, stopping

water flow to the nozzle. Water is routed down and out

the bottom distributor, up through the bed, and out the

top distributor to the drain. The fast flow (controlled by
a flow plug in the drain fitting) flushes dirt, sediments,
iron deposits, remaining brine and hardness to the
drain.