Program the timer, Note, 2 ppm iron x 5 = 10 (times) – Kenmore GENIUS II 625.34867 User Manual

Page 7: 15 gpg hardness ±10, 25 hardness number, Set recharge (regeneration) time, Set clean feature option, Nrc 1, Water softener start-up 1c. program the timer, 10 25 hardness number

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

SECTION 1

WATER SOFTENER START-UP

1C.

PROGRAM THE TIMER

■ Press the 0 UP/DOWN 0 buttons to set your
water hardness number in the display. The DOWN
button moves the display to 1. The UP button moves

the display to the highest setting (see maximum setting
for your model in the specifications).

NOTE:

If your water supply contains iron, compensate for it
by adding to the water hardness number. For example,
assume your water is 15 gpg bard and contains 2 ppm
iron. Add 5 to the hardness number for each 1 ppm of

iron. In this example, you would use 25 for your
hardness number.

2 ppm iron X 5 = 10

(times)

15 gpg hardness

±10

25 HARDNESS NUMBER

NOTE:

Each press of the UP/DOWN button changes the
display by 1 between 1 and 25. Between 25 and the

highest number, the display changes 5 at a time...25,
30, 35, etc. Holding the UP or DOWN button in
changes the display twice each second.

3. SET RECHARGE (REGENERATION) TIME:

■ Press the #1 SELECT button to display 2:00 AM

(flashing) and RECHARGE TIME.

_'UU

THE

At the 2:00 AM RECHARGE TIME

setting, the softener begins regen­
eration (see pages 13 and 14) at
2:00 AM, ending about 4:30 AM.
This is a good time in most __________________

households because water is not being used (see
AUTOMATIC BYPASS, page 15). If a different
RECHARGE TIME setting would be better for your
household, do the following.

■ Press the ® UP/DOWN 0 buttons to set the
desired RECHARGE starting hour. Be sure to observe
the AM-PM as you did when setting the present time of
day.

NOTE:

Each press of the UP/DOWN buttons changes the
display 1 hour. Holding the buttons in changes the

display twice each second.

4. SET CLEAN FEATURE OPTION:

■ Press the SELECT button to display OFF

(flashing) and CLEAN.

'

7

6

5

4

3

2

;

O F F

CLEAN

M.r «tout

LfiCl

a

7

e

5

4

3

2

1

On

CLEAN

This feature is beneficial on water
supplies containing iron and/or

high amounts of sediments (sand,
silt, dirt, etc.). When set to ON, a

backwash and fast rinse cycle will
occur first, preceeding the nor­

mal regeneration sequence (see
page 13). This provides extra
cleaning of the resin bed before it

is regenerated with the salt brine.

To conserve water, if your water supply does not

contain iron or sediments, be sure this feature is set to
OFF. Use the UP / DOWN buttons to change the ON /

OFF displays.

5. SET SALT TYPE

(sodium chloride or potas­

sium chloride, see page 9):

■ Press the SELECT button to display nACl, the
default setting.

If you will use potassium chloride (KCi) instead of
standard sodium chloride (NaCl) water softener salt,
be sure to set KCI in the display using the UP button.
The KCI setting adjusts regeneration cycle times to
compensate for the variable dissolving rate of

potassium chloride.

iWr «(Ml

Lfva

' 'a

7

S

nRC 1

4

1

2

f

KC

■ Press the #1 SELECT button once again, to return
the present time, and RECHARGE TONIGHT in the
display.

M.7

aaui

tfVfl LTlfi

* a

7

$

5

:

39

-

AECKANCE TOMQNT

4

3

2

i

If you need help programming the timer, call toll free, number 1-800-426-9345.

See pages 10, 11 and 12 for other face plate timer features.

Advertising