7, Boilers may be factory

packaeed with a tankless heater coil

see figure below. This coil provides

instantaneous heating of water for domestic use - if proper burner and water supply line controls are used.

Tankless coils are meant to provide domestic hot water for intermittent draws, not continuous flow.

IMPORTANT

Do not use a tankless coil if your water is excessively hard with

lime or other deposits which will accumulate inside the coil.

When using a tankless coil, the boiler has been configured so the Honeywell L8124C Combination
Hi/Low Limit Aquastat Relay mounts on a thermowell (provided) which needs to be installed in the 3/4”

tapping on the tankless coil. By mounting the aquastat on the coil, the tankless coil performance is
maximized by making the burner respond more quickly to a call for domestic hot water. A tempering
valve (mixing valve) is also recommended as shown in figure below. A flow restrictor may be required

on the tankless coil inlet piping so that flow rates are matched to boiler heat input (see table below).

Boiler

Burner Firing

Input

Tankless

Model

Rate (gph)

(MBH)

Rating (gpm)t

3EW.65T

0.65

91

2.90

3EW.75T

0.75

105

3.00

3EW1.00T

1.00

140

3.25

4EW.90T

0.90

126

3.15

4EW1.25T

1.25

175

3.50

4EW1.50T

1.50

210

3.75

5EW1.20T

1.20

168

3.45

5EW1.75T

1.75

245

4.00

5EW2.00T

2.00

280

4.25

Gallons of water per minute heated from 40°F to I40°F with

200°F boiler water temperature, intermittent draw

UNTEUrtnCO HOT WATEJt

( «

„«««M ..M

HOT WATEH

TANKLESS COIL

CENTER LINE

or COLO TAP

r 10 ir

n—

TEMPEfHNC

valve

COLO

water

«NLtr

SHUT-Orr

VALVE

ty

u

ft' NPT

NPT '

CONTROL WELL

12