Kenmore 5EW1.75 User Manual

Page 22

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

BECKETT OIL BURNER. NOZZLE. AND AIR SETTINGS

BOILER

DELEVAN

FIRING

HEAD-ADJ.

LOW FIRE

AIR

STATIC

OIL

MODEL

OIL NOZZLE RATE (gph)

OR SETTING

BAFFLE

SHUTTER / BAND

PLATE

BURNER

3EW.65*

0.50-80° B

0.65

FO - 1 1/8

YES

10/0

3-5/8

AFG F-HEAD

3EW.75

0.65-70'B

0.75

F3 - 1 1/8

YES

10/0

3-1/2

AFG F-HEAD

3EW1.00

0.85-70°B

1.00

F3 - 1 1/8

NO

10/2

3-1/2

AFG F-HEAD

4EW.90

0.75-80°A

0.90

F3 - 1 1/8

NO

8/0

3-1/2

AFG F-HEAD

4EW1.25

1.00-80°A

1.25

F6 - 1 1/8

NO

10/0

3-3/8

AFG F-HEAD

4EW1.50

1.25-80°A

1.50

F6 - 1 1/8

NO

10/2

3-3/8

AFG F-HEAD

5EW1.20

1.00-60°8

1.20

0

NO

10/1.5

2-3/4

AFG 50 MD

5EW1.75

1.50-45°B

1.75

2

NO

10/4

2-3/4

AFG 50 MD

5EW2.00

1.65-60°B

2.00

4

NO

10/5

2-3/4

AFG 50 MD

*To fire the SEW.65 on rate, the oil pressure must be increased to 175 psig.

All Beckett oil burners for the EW boiler are factory preset at 140 psig.

CARLIN OIL BURNER. NOZZLE. AND AIR SETTINGS

BOILER

DELEVAN ■ FIRING

HEAD

A)R BAND

CARLIN

MODEL

OIL NOZZLE RATE (gph)

SETTING

SET POINT

BURNER*

3EW.65

0.55-70°B

0.65

0.50

0.52

EZ-1 HP

3EW.75

0.65-60°B

0.75

0.60 / 0.65

0.60

EZ-1 HP

3EW1.00

0.85-60°B

1.00

0.85 /1.00

0.80

EZ-1 HP

4EW.90

0.75-60° B

0.90

0.75

0.75

EZ-1 HP

4EW1.25

1.00-60°B

1.25

0.85/1.00

0.90

EZ-1 HP

4EW1.50

1.25-60°B

1.50

1.10/1.25

1.25

EZ-1 HP

5EW1.20

1.00-60°B

1.20

0.85/1.00

0.90

EZ-1 HP

5EW1.75

1.50-60°B

1.75

1.50

1.65

EZ-2 HP

5EW2.00

1.65-70°B

2.00

1.65/1.75

1.95

EZ-2 HP

*All Carlin EZ-1 HP and EZ-2 HP oil burners are factory preset at 150 psig.

RIELLO 40 OIL BURNER. NOZZLE. AND AIR SETTINGS

BOILER

DELEVAN

FIRING

TURBULATOR/AIR OIL PRESSURE

RIELLO 40

MODEL

OIL NOZZLE RATE (gph) SHUTTER SETTING

(PSIG)*

BURNER MODEL

3EW.65

0.50-70°W

0.65

0.5/ 2.0

155

F5

3EW.75

0.65-70°W

0.75

2.0 / 2.2

150

F5

3ËW1.00

0.85-70°W

1.00

2.0/3.2

170

F5

4EW.90

0.75-70°W

0.90

1.5/2.6

160

F5

4EW1.25

1-00-70°W

1.25

2.5/3.8

170

F5

4EW1.50

1.25-70°W

1.50

4.0/7.0

175

F5

5EW1.20

1.00-70°W

1.20

2.5 / 3,5

150

F5

5EW1.75

1.50-70“W

1.75

2.0 / 3.8

155

F10

5EW2.00

1.75-70°W

2.00

2.5/4.1

155

F10

*AII Riello 40 F5 and F10 oil burners are factory preset at 145 psig.

NOTE; All burners use an insertion depth of 2-1/4" and fired at a

overfire draft of -0.02 inches w.c. The burner settings provided

are intended for initial start up only. Final adjustment must be made

using combustion test instruments.______________________________________

38

Advertising
This manual is related to the following products: